0118 |
slll slls |
Combustion air motor speed too low or out of tolerance |
Replace combustion air motor kit |
|
0119 |
slll slll |
Combustion air motor speed too high or out of tolerance |
Replace combustion air motor kit |
|
0120 |
slll lsss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0121 |
slll lssl |
Flame unstable during operation |
Ensure gas supply with correct operating pressure |
|
0122 |
slll lsls |
Gas supply interrupted |
Ensure gas supply with correct operating pressure |
|
0123 |
slll lsll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0124 |
slll llss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0125 |
slll llsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0126 |
slll llls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0127 |
slll llll |
- Combustion air motor faulty - Cable harness faulty - Fault in the electronics |
Replace combustion air motor |
|
0128 |
lsss ssss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0129 |
lsss sssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0130 |
lsss ssls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0131 |
lsss ssll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0133 |
lsss slsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0134 |
lsss slls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0135 |
lsss slll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0136 |
lsss lsss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0137 |
lsss lssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0138 |
lsss lsls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0139 |
lsss lsll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0140 |
lsss llss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0141 |
lsss llsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0142 |
lsss llls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0143 |
lsss llll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0144 |
lssl ssss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0145 |
lssl sssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0146 |
lssl ssls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0147 |
lssl ssll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0148 |
lssl slss |
Electronics blocked: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C |
- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace |
|
0149 |
lssl slsl |
Fault: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C |
- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace |
|
0150 |
lssl slls |
Fault: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C |
- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace |
|
0160 |
lsls ssss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0161 |
lsls sssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0162 |
lsls ssls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0163 |
lsls ssll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0164 |
lsls slss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0165 |
lsls slsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0166 |
lsls slls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0167 |
lsls slll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0168 |
lsls lsss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0169 |
lsls lssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0170 |
lsls lsls |
- Power supply not constant - Ignition spark interferes with electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0171 |
lsls lsll |
Ignition spark interferes with electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0172 |
lsls llss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0173 |
lsls llsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0174 |
lsls llls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0175 |
lsls llll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0176 |
lsll ssss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0177 |
lsll sssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0178 |
lsll ssls |
Ignition spark interferes with electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0180 |
lsll slss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0181 |
lsll slsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0182 |
lsll slls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0183 |
lsll slll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0184 |
lsll lsss |
Heater gets too hot or combustion air temperature sensor shows incorrect value |
Check / replace combustion air thermostat plate |
|
0186 |
lsll lsls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0187 |
lsll lsll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0188 |
lsll llss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0189 |
lsll llsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0190 |
lsll llls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0191 |
lsll llll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0192 |
llss ssss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0193 |
llss sssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0194 |
llss ssls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0195 |
llss ssll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0196 |
llss slss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0197 |
llss slsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0198 |
llss slls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0199 |
llss slll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0200 |
llss lsss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0201 |
llss lssl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0202 |
llss lsls |
- Flame out or not recognised - Faulty power supply earth connection |
Ensure gas supply with correct operating pressure |
|
0203 |
llss lsll |
Ionisation voltage present in Standby mode |
Check / replace solenoid valve (stuck in the Open position) |
|
0206 |
llss llls |
AC voltage components in the supply voltage |
Check for AC voltage components that can be generated by the power supply unit or solar system |
|
0207 |
llss llll |
AC voltage components in the supply voltage |
Check for AC voltage components that can be generated by the power supply unit or solar system |
|
0208 |
llsl ssss |
Combustion air motor speed too low or out of tolerance |
Replace combustion air motor kit |
|
0209 |
llsl sssl |
Combustion air motor speed too high or out of tolerance |
Replace combustion air motor kit |
|
0210 |
llsl ssls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0211 |
llsl ssll |
Flame unstable during operation |
Ensure gas supply with correct operating pressure |
|
0212 |
llsl slss |
Gas supply interrupted |
Ensure gas supply with correct operating pressure |
|
0213 |
llsl slsl |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0214 |
llsl slls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0215 |
llsl slll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0216 |
llsl lsss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0217 |
llsl lssl |
- Combustion air motor faulty - Cable harness faulty - Fault in the electronics |
Replace combustion air motor |
|
0218 |
llsl lsls |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0219 |
llsl lsll |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |
|
0220 |
llsl llss |
Fault in the electronics |
Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system. |