Error Codes 0221-0621

0221

llsl llsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0223

llsl llll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0224

llls ssss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0225

llls sssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0226

llls ssls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0227

llls ssll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0228

llls slss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0229

llls slsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0230

llls slls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0231

llls slll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0232

llls lsss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0233

llls lssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0234

llls lsls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0235

llls lsll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0236

llls llss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0237

llls llsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0238

llls llls

Electronics blocked: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C

- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace

0239

llls llll

Fault: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C

- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace

0240

llll ssss

Fault: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C

- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace

0255

llll llll

- No connection between heater and control panel - Heater has no 12 V power supply - Control panel cable faulty

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0301

sl ssls llsl

12 V power supply faulty (overvoltage)

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0302

sl ssls llls

12 V power supply faulty (low voltage)

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0303

sl ssls llll

Risk of low voltage. Battery voltage too low < 10.4 V

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0304

sl ssll ssss

Relighting, normal combustion behaviour

No action required

0305

sl ssll sssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0401

sl lssl sssl

Warning Water overheat condition

Switch off heater and allow it to cool down. Fill boiler with water

0402

sl lssl ssls

Warning Air overheat condition

Inspect the individual discharge openings / remove blockage to circulated air intake

0407

sl lssl slll

230 V power supply faulty

Ensure 230 V power supply at appliance input

0408

sl lssl lsss

Gas supply interrupted in Mix mode

Ensure gas supply with correct operating pressure

0411

sl lssl lsll

Risk of low voltage. Battery voltage too low < 10.4 V

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0412

sl lssl llss

- Window switch detects open window - Bridge for window switch on Truma electronics interrupted

- Close window - Check / replace window switch with cable

0413

sl lssl llsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0414

sl lssl llls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0417

sl lsls sssl

12 V power supply faulty (overvoltage)

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0418

sl lsls ssls

12 V power supply faulty (low voltage)

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0420

sl lsls slss

230 V power supply faulty (overvoltage)

Ensure 230 V power supply at appliance input

0421

sl lsls slsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0422

sl lsls slls

Power reduction active

Not all warm air outlets used. Inspect the individual openings / remove blockage to circulated air intake

0501

sl llll slsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0502

sl llll slls

Heater gets too hot or combustion air temperature sensor shows incorrect value

Check / replace combustion air thermostat plate

0503

sl llll slll

Heater gets too hot or combustion air temperature sensor shows incorrect value

Check / replace combustion air thermostat plate

0504

sl llll lsss

Combustion air temperature sensor out of tolerance

Check / replace combustion air thermostat plate and cable harness

0505

sl llll lssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0506

sl llll lsls

Combustion air motor speed out of tolerance

Replace combustion air motor kit

0507

sl llll lsll

Gas supply interrupted

Ensure gas supply with correct operating pressure

0508

sl llll llss

Ionisation voltage present in Standby mode

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0509

sl llll llsl

Ignitor current too high

Replace ignitor

0510

sl llll llls

Solenoid valves incorrectly controlled

Replace cable harness

0511

sl llll llll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0512

ls ssss ssss

Air temperature switch opened during operation due to overheating

- Check heat exchanger for overheating damage - Check water container for frost damage - Check temperature monitoring cable harness for damage, replace if necessary

0513

ls ssss sssl

Water temperature switch opened during operation due to overheating

Check the connector latching of the contacts in plug X1

0514

ls ssss ssls

Fault due to power interruption during operation

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0515

ls ssss ssll

Combustion air motor speed out of tolerance

Replace combustion air motor kit

0516

ls ssss slss

Gas supply interrupted

Ensure gas supply with correct operating pressure

0517

ls ssss slsl

Gas supply interrupted

Ensure gas supply with correct operating pressure

0520

ls ssss lsss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0521

ls ssss lssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0522

ls ssss lsls

Combustion air motor speed out of tolerance

Replace combustion air motor kit

0523

ls ssss lsll

Ignitor current too high

Replace ignitor

0524

ls ssss llss

Combustion air motor short circuit

Check / replace combustion air motor

0525

ls ssss llsl

Combustion air motor current too high

Check / replace combustion air motor

0526

ls ssss llls

Combustion air motor current too low

Check / replace combustion air motor

0527

ls ssss llll

Ignitor current too low

Replace ignitor

0528

ls sssl ssss

2 KW solenoid coil current too high

Replace cable harness

0529

ls sssl sssl

4 KW solenoid coil current too high

Replace cable harness

0530

ls sssl ssls

Safety valve solenoid coil current too high

Replace cable harness

0531

ls sssl ssll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0532

ls sssl slss

2 KW solenoid coil current too high

Replace cable harness

0533

ls sssl slsl

4 KW solenoid coil current too high

Replace cable harness

0534

ls sssl slls

Safety valve solenoid coil current too high

Replace cable harness

0535

ls sssl slll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0536

ls sssl lsss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0537

ls sssl lssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0538

ls sssl lsls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0539

ls sssl lsll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0540

ls sssl llss

During the self test: 12 V power supply faulty (overvoltage)

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system

0541

ls sssl llsl

During the self test: 12 V power supply faulty (low voltage)

Ensure 12 V voltage under load at the appliance input and check for AC voltage components that can be generated by the power supply unit or solar system

0542

ls sssl llls

During the self test: Risk of low voltage. Battery voltage too low < 10.4 V

Ensure 12 V voltage under load at the appliance input and check for AC voltage components that can be generated by the power supply unit or solar system

0543

ls sssl llll

During the self test: Relighting, normal combustion behaviour

No action required

0544

ls ssls ssss

During the self test: Fault in the electronics

Replace the electronics, enter heater serial number on the new electronics using the Truma Diagnose Tool

0601

ls slsl lssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0602

ls slsl lsls

Fault in the electronics

Replace the electronics, enter heater serial number on the new electronics using the Truma Diagnose Tool

0603

ls slsl lsll

Electronics blocked: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C

- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace

0604

ls slsl llss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0605

ls slsl llsl

Fault: - Because air temperature switch and / or water temperature switch has opened during operation due to overheating - Because combustion air temperature sensor signals temperatures > 215 °C

- Check heat exchanger for overheating damage - Check water container for frost damage - Check / replace water temperature cable harness - Check thermostat plate LTF for damage / replace

0606

ls slsl llls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0607

ls slsl llll

Maximum number of fault resets reached The appliance is blocked if there are more than 4 fault resets within 15 minutes.

Press the button (Service) on the electronics. Use Diagnose Tool to read out and remedy faults that caused the block.

0608

ls slls ssss

CP Plus initialisation does not match the heater

Reinitialise CP Plus

0609

ls slls sssl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0610

ls slls ssls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0611

ls slls ssll

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0612

ls slls slss

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0613

ls slls slsl

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0614

ls slls slls

Fault in the electronics

Ensure 12 V voltage under load at appliance input and check for AC voltage components that can be generated by the power supply unit or solar system.

0615

ls slls slll

   

0616

ls slls lsss

   

0617

ls slls lssl

Electronics blocked: Because combustion air temperature sensor signals temperatures > 215 °C

- Check heat exchanger for overheating damage - Check water container for frost damage - Check combustion air temperature sensor thermostat plate for damage / replace

0619

ls slls lsll

Water temperature sensor out of tolerance

Replace water temperature monitoring cable harness

0620

ls slls llss

Air temperature sensor out of tolerance

Check / replace temperature monitoring cable harness

0621

ls slls llsl

Room temperature sensor out of tolerance

Check cable for room temperature sensor and plug connections